In order to fix this leaking around the handle,
you first remove the screw that holds the handle
on to the valve stem. Next, you remove the
packing nut - a large adjustable wrench will work.
Then you need to remove the old packing gasket
material and the brass packing washer.
Clean up the brass packing washer and replace the
packing washer, if you can find one in the size
you need. Look for a flat packing washer in your
hardware store. You can also check with a plumbing
supply jobber. It doesn't have to be the grey
clay-like material that you removed. I searched
many stores without success. I fashioned a new
packing washer out of 1/8" thick rubber, and it
worked fine. Make sure you put some thread dope
on the packing nut threads before you re-install
it. Don't over-tighten the packing nut; stop when
you get resistance. The rubber material will fill
the gap very nicely, and the leaking around the
handle should have stopped competely. There is
nothing wrong with the design of the faucet. The
correct order of re-installing these parts is:
(1) the brass packing washer
(2) the new packing gasket material
(3) the packing nut
(4) the handle
The packing nut needs to be tightened around the stem, if that doesn't do it, the packing needs to be replaced.
http://www.rd.com/advice-and-know-how/stepbystep-instructions-and-pictures-of-how-to-stop-a-freezeproof-faucet-from-leaking/article117717.html
Tuesday, April 13, 2010
Wednesday, February 3, 2010
Fixing window blinds ?Ladder Barrel Drum

http://www.fixmyblinds.com/cgi-bin/ez-catalog/cat_display.cgi?82X339232
http://www.blindsparts.com/servlet/Categories?category=BLINDS%5C%3ADrums%26Cradles&searchpath=2392728&start=91&total=122
TILTERS
http://www.blindsparts.com/servlet/Categories?category=BLINDS%5C%3ADrums%26Cradles&searchpath=2392728&start=91&total=122
Barrels
Cord Locks
Miscellaneous
Mounting Brackets
Restring Kits
Slats and Valance
Tilters
Valance Clips
http://www.fixmyblinds.com/cgi-bin/ez-catalog/cat_display.cgi?82X339232
Replacement Metal Drum for 2" Hunter Douglas Wood Blinds with string ladders.Only Metal Drums Sold. This is a replacement for plastic drum on right.
Old Plastic Metal Drum - Not Available
Price:$3.00
Stock #:DRUM-01
Crimpable Clasps for String Ladders.These are used to attach the tops of the ladders to the drum inside the headrail of the blind.Two needed per cut-ladder section.
Price:$0.25
http://dgwindowshine.en.alibaba.com/search/product?IndexArea=product_en&SearchText=drum
http://www.blindsparts.com/servlet/Categories?category=BLINDS%5C%3ADrums%26Cradles&searchpath=2392728&start=91&total=122
TILTERS
http://www.blindsparts.com/servlet/Categories?category=BLINDS%5C%3ADrums%26Cradles&searchpath=2392728&start=91&total=122
Barrels
Cord Locks
Miscellaneous
Mounting Brackets
Restring Kits
Slats and Valance
Tilters
Valance Clips
http://www.fixmyblinds.com/cgi-bin/ez-catalog/cat_display.cgi?82X339232
Replacement Metal Drum for 2" Hunter Douglas Wood Blinds with string ladders.Only Metal Drums Sold. This is a replacement for plastic drum on right.
Old Plastic Metal Drum - Not Available
Price:$3.00
Stock #:DRUM-01
Crimpable Clasps for String Ladders.These are used to attach the tops of the ladders to the drum inside the headrail of the blind.Two needed per cut-ladder section.
Price:$0.25
http://dgwindowshine.en.alibaba.com/search/product?IndexArea=product_en&SearchText=drum
Friday, January 15, 2010
Concentric vent

You may want to consider using a "concentric vent" that handles both combustion air and exhaust through the same 4" opening in the outside wall. I just installed a 95% Lennox using this vent and it has performed well during the coldest period this winter ( lows to -20F ). The vent is Lennox part #71M80 and is called a 1.5" concentric vent kit. I am familiar with ice buildup on the standard 2" exhaust vents in a cold climate, I used several Lennox Pulse in Fargo, ND in the 1980's but can't say they ever iced up to the point of shutting down the furnace.
The concentric vent ties in to both the 2" combustion air line and the 2" exhaust right before it goes out of the wall through a 4' diameter hole. The exhaust goes out through the middle of this concentric vent and once outside is reduced down to 1 1/2", at a length of 8". The fresh air intake is right near the siding and is the outer portion of this vent, the exhaust keeps this whole unit warm. One other important point is the whole venting system is sloped back to the furnace so no condensation drips from the exhaust vent outside.
Saturday, January 9, 2010
Furnace intake clogged by ice crystals during extremely cold week
You can see moisture freezing onto those plant stems. Temp is below 10F

Warm exhaust makes a bare spot on the ground below.
Moisture freezing on the bush to the right which is over 10 ft away. sort of like hoar frost.
Picture with furnace running so you can see the steam.
In windless condition, the steam goes everywhere. Tends to flow right because the AC blocks the left side.

Added another shroud over the intake pipe. This might decrease the number of ice crystals entering the intake without restricting the air flow. Plus when there is a blizzard coming from the right side, less snow will enter the intake opening.
I might try a length of black perforated drain pipe, maybe 4 ft. That would create a protected zone to suck air from. Unrestricted, but decrease the number of ice crystals and snow entering the intake opening. The black pipe might get heated by sunshine and help evaporate snow and ice that gets into the pipe.
Sunday, January 3, 2010
Friday, January 1, 2010
Delta shower faucet and tub spout--No hot water
Turn off main water valve first.
Big chrome ring should unscrew readily counterclockwise. Do not force it, because those teeny copper tubes behind the valve will twist off or pinch.

Copper tubes visible here.
Didn't get a picture, but there was a pea gravel sized chunk of rust in the hot water valve side.
That was enough to choke off hot water flow.
Old tub spout did not want to come off. I started cutting it off. Here is the little 1/2 inch pipe stub the spout attaches to. The threads were totally gunked up with plumbers putty or something.
Big chrome ring should unscrew readily counterclockwise. Do not force it, because those teeny copper tubes behind the valve will twist off or pinch.
Copper tubes visible here.
Didn't get a picture, but there was a pea gravel sized chunk of rust in the hot water valve side.
That was enough to choke off hot water flow.
Old tub spout did not want to come off. I started cutting it off. Here is the little 1/2 inch pipe stub the spout attaches to. The threads were totally gunked up with plumbers putty or something.
Saturday, December 19, 2009
AO Smith water heaters
Your search results for plumbers located in San Jose, CA.
Water Clarity Plumbing Nick Satalino 390 Floyd Street San Jose, CA 95110 408-275-9300 www.waterclarityplumbing.com
South Valley Plumbing Tom Fortin 3591 Charter Park Drive San Jose, CA 95136 408-265-5556 www.972leak.com
Affordable Plumbing Solutions Richard Elisary 117 Bernal Road #70-172 San Jose, CA 95119 408-972-5325 mailto:service@affordableplumbingsolutions.netwww.972leak.com
Heritage Plumbing & Heating Jim Nachtigal 6140 Geronimo Dr San Jose, CA 95123 408-592-0452 mailto:heritage2@comcast.netHeritageHeatAndAir.Com
AAA Mike Counsil Plumbing, Inc. Angelo Segretto 1915 O'Toole Way San Jose, CA 95131 408-272-4900 mailto:askmike@mcplumbing.comhttp://www.mcplumbing.com
Great Western Plumbing Charles Herring 6017 Snell Ave #336 San Jose, CA 95123 408-241-8084 mailto:TraderC@dslextreme.com
Plumbwerx Plumbing Theodore Amor 761 Mabury Rd, Suite 40 San Jose, CA 95133 408-441-0307 mailto:info@plumbwerx.comwww.plumbwerx.com
Falcone Plumbing & Heating, Inc. Mike Falcone 650 Lincoln Ave. #B San Jose, CA 95126 408-292-9705 mailto:Mike@callfalcone.comcallfalcone.com
http://www.hotwater.com/sales/pca.aspx
http://www.972leak.com/SpecialOffers.html $50 off
Water Clarity Plumbing Nick Satalino 390 Floyd Street San Jose, CA 95110 408-275-9300 www.waterclarityplumbing.com
South Valley Plumbing Tom Fortin 3591 Charter Park Drive San Jose, CA 95136 408-265-5556 www.972leak.com
Affordable Plumbing Solutions Richard Elisary 117 Bernal Road #70-172 San Jose, CA 95119 408-972-5325 mailto:service@affordableplumbingsolutions.netwww.972leak.com
Heritage Plumbing & Heating Jim Nachtigal 6140 Geronimo Dr San Jose, CA 95123 408-592-0452 mailto:heritage2@comcast.netHeritageHeatAndAir.Com
AAA Mike Counsil Plumbing, Inc. Angelo Segretto 1915 O'Toole Way San Jose, CA 95131 408-272-4900 mailto:askmike@mcplumbing.comhttp://www.mcplumbing.com
Great Western Plumbing Charles Herring 6017 Snell Ave #336 San Jose, CA 95123 408-241-8084 mailto:TraderC@dslextreme.com
Plumbwerx Plumbing Theodore Amor 761 Mabury Rd, Suite 40 San Jose, CA 95133 408-441-0307 mailto:info@plumbwerx.comwww.plumbwerx.com
Falcone Plumbing & Heating, Inc. Mike Falcone 650 Lincoln Ave. #B San Jose, CA 95126 408-292-9705 mailto:Mike@callfalcone.comcallfalcone.com
http://www.hotwater.com/sales/pca.aspx
http://www.972leak.com/SpecialOffers.html $50 off
Subscribe to: