Thursday, April 18, 2019

Runningbrook

kitchen drawer slides broken

2 dings in kitchen sink porcelain

bottom wood of frame missing

mini blind over kitchen sink

old stove --pretty beat up

vertical blinds missing  window +  sliding patio doorway

AC filter in ceiling?   very dirty grill

2-3 handrails  loose up stairway

blinds in master BR

sink ding  master   right sink

master shower  caulk


BR  far end--pleated blinds

2 door latches need lube-- doesnt latch  incl hall closet

carpet condition lower LR

carpet seam near laundry room

worn spot carpet  near sliding patio door

Thursday, April 4, 2019

Arbor job








Safety glass panel in Shower/Tub

10 5/8 x 54             3/8 in thickness




upper attachment

2 lower attachments

screw seems to go through a hole in the glass



notch cut in glass



clear gasket




image.png


image.png

Tuesday, April 2, 2019

Barden

Befiore mowing:   left side of lawn a little taller/weedier 

weed patches


hand pulling weeds


string trimmed weeds along the fence

trimmed along fence, weeded

Monday, February 4, 2019

garage driveway puddle

large puddle betw  doors 3+2

water puddle inside gate

where is this water coming from??    since downspout is being pumped to the street.
some from the driveway channel?   ground water saturated?


Place that pump where the puddle is deepest.   That way, less water can get into the garage.

note puddling in front yard--requires a french drain

no water coming out of that surface drain pipe in the rear  corner--strange

the channel drain in the driveway--connects to what??

I will dig down to see if I can find the connection to a pipe.   I  already poked a long screwdriver into the mud, and felt nothing down 8 inches,  except maybe something hard  right below that channel.   If that is a PVC pipe, it felt rather small  like 1-2 inch pipe.

If the channel drain in the driveway will  allow the water in the big puddle to convey towards the gate,  this would be the first step to solving the problem.

I did stick something into the channel drain, and it seemed to be 3-4 inches deep.   pretty substantial.   as if there might be a 3-4 inch pipe embedded in the concrete driveway.



outlet from channel drain goes down below slab,  then 45 degree angle towards the fence.

the small hole in middle, i hit a big root   3-4 inch diameter.  but no sign of the plastic drain pipe.

dug where the corrugated drain pipe might go towards the fence, but did not find it.

Monday, December 10, 2018

Phister shower 0x8


















image.png


I BELIEVE YOURS POINTS AT 9 O'CLOCK, RIGHT?


image.png

============================================
THAT MATCHES WHAT I SAW YESTERDAY.
EVEN WHEN I OPEN THE SHOWER JUST A LITTLE, THE WATER SEEMED WARM.     NO  COLD ONLY.

CANNOT GET ONLY HOT WATER.   ALL YOU GET IS THE MIX OF HOT/COLD SUPPLY LINES.

IF THIS IS INDEED THE CASE,  THEN  HOT AND COLD CONNECT TO THE TRUE SHOWER AND TUB SPOUT PORTS,  

WHICH WOULD MEAN THEY ARE DIRECTLY CONNECTED TO EACH OTHER, EVEN WHEN THE SHOWER VALVE IS TURNED OFF.

MEANING:   WIDE OPEN CROSSOVER.

Wednesday, December 5, 2018

Lukewarm shower: Crossover in Pressure Balance

ABSTRACT Crossover allows the unintended flow of hot water into the cold water system, and vice versa, and may have a significant impact on energy losses in the system, particularly in central DHW systems in multifamily and commercial buildings. In a CEC funded study of over 100 multifamily buildings throughout California, over 50% exhibited crossover failures in their central DHW distribution. This occurs most often when a cartridge in a shower or faucet’s mixing valve wears out and is no longer able to effectively control the mix of hot and cold water at a fixture or point of use. Many times these issues are asymptomatic and the effects not readily felt by the user. 

[aceee.org

The Eatherton method, which is properly named after Mark Eatherton, the plumbing engineer who created this particular procedure, consists of testing each fixture individually, beginning with the shower valve in the housing unit that is experiencing hot water issues The faceplate of the shower valve is removed, leaving the shower’s mixing valve exposed. The hot side of the shower valve is heated by turning on hot water until the user gets the hottest water and then turning the shower valve back off. A nearby lavatory hot water faucet is then turned on, while the user feels the hot side of the exposed shower’s mixing valve. If there is crossover, the shower mixing valve will rapidly cool down because the lavatory is pulling cold water through the shower mixing valve, thus rapidly cooling down the hot side of the shower mixing valve. If no crossover exists, the shower mixing valve will remain hot, because cold water is not crossing over, and thus the shower valve will remain heated. 

Pressure balancing failure crossover: PRICE-PFISTER SHOWER VALVE!!!!! 
[www.youtube.com

Is it possible for a faulty shower to pump hot water back into the cold water supply line? 
Yes this is possible if the pressure balanced valve or thermostatic valve goes bad. A bad valve could create a hot and cold crossover which will force hot water back into the cold water line. 

A plumbing cross over is a condition whereby cold water is allowed to flow into the hot water system. The plumbing system in a home is divided into two sub-systems, the hot water supply and the cold water supply. ... A plumbing cross-over can cause a complaint such as 'water not hot enough'. 

Crossover is a term that is used when the hot water “crosses over” to the cold or the cold water “crosses over” to the hot. The frequency of customers calling in with these symptoms is increasing. Having some hot water mixed with your cold is not necessarily an urgent situation, but it does indicate that there is a problem and it is certainly not energy efficient. Having cold water crossing over into your hot water lines often results in a lukewarm shower and that usually gets everyone’s attention! 
[www.bcpsi.com

Single handled shower faucets have a mixing area inside valve where hot and cold come together before going into sink. 
This mixing valve can have crossover where the hot and cold can pass through to each other even when faucet handle is off. When single handle faucets get old, this can happen. 

How it happens: 
For example another faucet is turned on inside house, and pressure differential between hot and cold causes hot water at shower handle to pass through mixing area and into cold water line. or vice versa 
[www.fixya.com]

Repair a Shower Anti-Scald Pressure Balancer - This Old House

https://www.plbg.com hot water only lukewarm - faulty valve?

Image result for pfister pressure balance valve exploded diagram disassembled